IMicrocuvette yeHemoglobin Analyzer

Inkcazelo emfutshane:

Ukusetyenziswa okucetywayo

◆I-microcuvette isetyenziswa kunye ne-H7 series hemoglobin analyzer ukukhangela ubungakanani be-hemoglobin egazini lomntu wonke.

Umgaqo wovavanyo

◆I-microcuvette inendawo engqindilili esisigxina ukulungiselela isampuli yegazi, kwaye i-microcuvette ine-reagent yokuguqula ngaphakathi ukukhokela i-specimen yokuzalisa i-microcuvette.I-microcuvette egcwele i-specimen ifakwe kwisixhobo se-optical ye-hemoglobin analyzer, kwaye i-wavelength ethile yokukhanya ihanjiswa nge-specimen yegazi, kwaye i-hemoglobin analyzer iqokelela umqondiso we-optical kwaye ihlalutye kwaye ibala umxholo we-hemoglobin wesampuli.Umgaqo ongundoqo yi-spectrophotometry.


Iinkcukacha zeMveliso

I-Microcuvette ye-Hemoglobin analyzer

 

IMicrocuvette yeHemoglobin analyzer0

 

I-Hemoglobin analyzer microcuvette

 

Iinkcukacha zeMveliso:

◆ Izinto eziphathekayo: i-polystyrene

◆ Ubomi beShelf: iminyaka emi-2

◆ Ubushushu bokugcina: 2°C35°C

◆Ukufuma okuhambelanayo≤85%

◆ Ubunzima: 0.5g

◆Ukupakisha: 50 amaqhekeza/ibhotile

Ixabiso elihle/uluhlu lweReferensi yoLuhlu lweReferensi:

◆ Amadoda amadala: 130-175g/dL

◆Abafazi abadala: 115-150g/dL

◆Usana: 110-120g/dL

◆Umntwana: 120-140g/dL

Iziphumo zovavanyo

◆Uluhlu lokubonisa umlinganiselo yi-0-250g/L.I-coagulation inokubangela ukuba i-specimen yegazi ingaphumeleli ukuzalisa i-microcuvette, okukhokelela kwimilinganiselo engalunganga.

◆Hemolysis inokuchaphazela iziphumo zovavanyo.

Unyino lweNdlela yoVavanyo

◆ Ukuxilongwa kunye nonyango akufanele kuxhomekeke kuphela kwisiphumo sovavanyo.Imbali yeklinikhi kunye nolunye uvavanyo lwebhubhoratri kufuneka luthathelwe ingqalelo

Inkcazo yokuSebenza

◆Ayinanto:1g/L

◆Ukuphinda-phinda:ngaphakathi koluhlu lwe-30g / L ukuya kwi-100g / L, i-SD3g/L;phakathi koluhlu lwe-101g / L ukuya kwi-250g / L, i-CV1.5%

◆Umgca:ngaphakathi kuluhlu 30g / L ukuya 250g/L, r0.99

◆Ukuchaneka:I-coefficient yonxulumano (r) yovavanyo lothelekiso yi0.99, kunye nokutenxa ngokunxulumene5%

◆Umahluko phakathi kwebhetshi≤5g/L

Inkqubo yoVavanyo lwe-EDTA yegazi:

◆Iisampulu ezigciniweyo kufuneka zibuyiselwe kubushushu begumbi kwaye zixutywe ngocoselelo phambi kovavanyo.

◆Sebenzisa i-micropipette okanye i-pipette ukuzoba akukho ngaphantsi kwe-10μL yegazi kwisilayidi seglasi ecocekileyo okanye enye indawo ecocekileyo ye-hydrophobic.

◆ Ukusebenzisa i-tip ye-reagent ukudibanisa isampuli, isampuli ingena phantsi kwesenzo se-capillary kwaye igcwalise isiqwenga se-reagent.

◆Cima ngononophelo naziphi na iisampuli ezigqithisileyo kumphezulu we-microcuvette.

◆Faka i-microcuvette kwi-microcuvette holder ye-hemoglobin analyzer uze utyhale isibambi kwi-analyzer ukuqalisa umlinganiselo.